All standard vacuum lifters manufactured by ANVER are made to order using modular components. They are promptly shipped. There are literally hundreds combinations of ANVER Standard Vulcan Lifters available depending on the vacuum generator used. For help in sizing the right lifter, contact one of our skilled applications engineers.
GSS Machinery provides a complete line of vacuum lifters, vacuum lifting equipment and other vacuum machinery. You can find horizontal lifters as well as powered tilters or battery-powered lifters.
BMC-Series lifters have removeable pad extensions. For handling narrow and long loads, the vacuum pads can either be mounted inline or without the extensions. Operators can use this equipment comfortably for a wide variety of loads and applications thanks to its ergonomic handlebar and welded steel lifting frame.
Calculate the Required Length for Crossarms. Add 6 inches to the maximum load width. If the crossarm length is not standard, you can choose the next longest length.
ANVER is a leading manufacturer of Vacuum Tube Lifting systems in the United States with a wide selection of Vacuum Tube Lifters and Replacement Vacuum Tube Lifter Parts. We build a high-quality product that is designed for years of production use.
No power service is required for the mechanical self-powered, self-cycling vacuum lifters. Setup is simple
The entire ANVER line of powered vacuum generators comes with a range of electrical specifications. The vacuum generator's web page contains all relevant electrical information. Notice: All ANVER electrical components and controls follow international standards: UL. CSA. NFPA. NEC. It is the responsibility and responsibility of the user for complying with all local electrical codes applicable to the installation. North American Electrical Requirements: To Be Festooned (wire loops suspended from the overhead crane). Use a retractable or coil cord to bring power up to the hoist. The hoist is already powered up so you can just add power to it. As they came from the factory, it is best to keep the lifter pendant controls and the hoist separate. You can also supply generators in other voltages or phases by adding a transformer to the following voltages: 208V. Circuit breakers or fuses are used to protect generator motors that have a voltage less than 120V. Motors and other devices that consume more than 200V are fused or use thermal overload with a contractor.
When the vacuum level is reached, a green light will be lit to let you know that it is safe to lift. Once you are ready for the load to be placed, lower the unit so that the chain is loose enough to activate the switch. Now that vacuum has been released, you can raise the unit using the hoist controls. You are ready for the next lift.
AMC-Series lifters can be equipped with pad extensions that can be removed. For handling large and narrow loads, the pads can be mounted inline. The equipment features an ergonomic lifter handlebar with a welded-steel lifting frame that allows operators to use it with ease for many different loads and applications.
Vacuum Pumps. Vacuum Generators. Vacuum Stations. Vacuum Valves. Vacuum Valves. Vacuum Valves. Vacuum Valves. Vacuum Valves. Vacuum Vails and Switches. Vacuum Filters. Vacuum Mufflers. Vacuum Movers. Vacuum System Accessories. All at affordable prices.
EMC-Series lifters are equipped with removable pad extensions. Vacuum pads can be installed inline to handle long or narrow loads, or without extensions to handle short and narrow loads. This equipment is constructed with an ergonomic lifter handlebar, a welded steel lifting framework and can be used with ease for handling a variety of loads and applications.
ANVER, a leader in Vacuum Tube Lifting Systems in the United States, offers a large selection of Vacuum Tube Lifters as well as Replacement Vacuum Tube Lifter parts. Our products are built to last for many years.
The entire ANVER line of powered vacuum generators comes with a range of electrical specifications. The vacuum generator's web page contains all relevant electrical information. Notice: All ANVER components, controls, and wiring comply with international standards: UL. CSA. NFPA. NEC. It is the responsibility of the user to adhere to any additional local electrical codes that may apply to their installation. North American Standard Electricity Requirements. To be Festooned (wire loops hanging from overhead crane trolleys) to the Lifter. Power should be brought to the hoist, and then to the lifter via a retractable cable/coil cord. It is only a matter of adding power to the lifter, as you are already attached to the hoist. As they came from the factory, it is best to keep the lifter pendant controls and the hoist separate. Additional Voltages and Phases: Generators are available in the following voltages. A transformer can be added to supply these voltages: 208V. Circuit breakers or fuses are used to protect generator motors that have a voltage less than 120V. Motors and other devices that consume more than 200V are fused or use thermal overload with a contractor.
For more information contact GSS Machinery. Or fill out a Lifter Quote Request Form. A Sales Engineer should respond within a few hours.
Below hook lifters can be classified into three categories: pressure lifters and supporting lifters. Which option is best for you will depend on the type of material that you are moving.
Between 20 and 25 years. For optimal safety and efficiency, it is important to replace the operating panel, cables and traveling cables of your elevator when it reaches 20 years old.
Based on their method of operation, there are three types of vacuum gauges: mechanical, thermal conductivity and ionization. We will be focusing on the thermal conductivity, ionization and ionization gauges in this discussion. Vacuum furnaces rarely use purely mechanical vacuum gauges.
Platform lifts are used to transport heavy loads from one floor to the next. These platforms are popular in factories, warehouses, schools, and hospitals, among other places. They are also called reach lifts, scissor lifts, or reach lifts.